I have a server that had a failed drive and a drive in Predictive Failure. I replaced the failed drive and it was rebuilding.
root@linux:~ # hpacucli ctrl all show config
Smart Array E200 in Slot 3 (sn: PA6C9%%BFTWZMV)
array A (SAS, Unused Space: 0 MB)
logicaldrive 1 (410.1 GB, RAID 5, Recovering, 1.4% complete)
physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, Predictive Failure)
physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, Rebuilding)
physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 146 GB, OK)
physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 146 GB, OK)
Now the LUN is stuck at the status Ready for Rebuild. Is there anything that I can do besides rebooting the server?
root@linux:~ # hpacucli ctrl all show config
Smart Array E200 in Slot 3 (sn: PA6C9%%BFTWZMV)
array A (SAS, Unused Space: 0 MB)
logicaldrive 1 (410.1 GB, RAID 5, Ready for Rebuild)
physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, Predictive Failure)
physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, Predictive Failure)
physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 146 GB, OK)
physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 146 GB, OK)