I have a 3ware RAID controller running a RAID-10.
I have a disk that currently has a SMART-FAILURE
. I've ran a /c0 rescan
and the Status will change to OK then back to SMART-FAILURE
> /c0 show
Unit UnitType Status %RCmpl %V/I/M Stripe Size(GB) Cache AVrfy
------------------------------------------------------------------------------
u0 RAID-1 OK - - - 931.312 RiW OFF
u1 RAID-10 OK - - 256K 3725.25 RiW OFF
u3 SPARE OK - - - 931.505 - OFF
VPort Status Unit Size Type Phy Encl-Slot Model
------------------------------------------------------------------------------
p0 OK u0 931.51 GB SATA 0 - ST1000DM005 HD103SJ
p1 OK u0 931.51 GB SATA 1 - ST1000DM005 HD103SJ
p3 OK u1 931.51 GB SATA 3 - ST1000DM005 HD103SJ
p4 OK u1 931.51 GB SATA 4 - ST1000DM005 HD103SJ
p5 OK u1 931.51 GB SATA 5 - ST1000DM005 HD103SJ
p6 OK u1 931.51 GB SATA 6 - ST1000DM005 HD103SJ
p7 OK u1 931.51 GB SATA 7 - ST1000DM005 HD103SJ
p8 SMART-FAILURE u1 931.51 GB SATA 8 - ST1000DM005 HD103SJ
p9 OK u1 931.51 GB SATA 9 - ST1000DM005 HD103SJ
p10 OK u1 931.51 GB SATA 10 - ST1000DM005 HD103SJ
p11 OK u3 931.51 GB SATA 11 - ST1000DM005 HD103SJ
I've done some research on how to replace a disk but can't find any documentation that I've found doesn't go into how to replace the disk with a spare unit.
How do I replace the p8 disk with the u3 unit?